Overview

The Vatech Green 16 and 18 are advanced 4-in-1 digital X-ray systems offering CBCT, Pano, Ceph and model scanning. With low radiation output and high-resolution imaging, they deliver accurate diagnostic results while enhancing patient safety and satisfaction. The Green 16 offers a maximum FOV of 16x9 cm and the Green 18 extends this to 18x10 cm, catering to a wide range of clinical needs from endodontics to full arch and TMJ analysis. Featuring fast scan times, metal artifact reduction and the user-friendly Ez3D-i software, these units elevate both diagnostic confidence and workflow efficiency.

Key Features

Key features:

  • Low-dose imaging with high diagnostic quality

  • Multi FOV options from 5×5 to 18×10 cm

  • 4-in-1 system: CBCT, Pano, Ceph (optional) and Model Scan

  • Green scan time minimizes motion artifacts

  • ART-V reduces metal artifacts

  • Ez3D-i software enables airway and TMJ analysis

  • 3D scanning for digital model storage

  • Insight Pan function and advanced workflow

Description

Advanced 4-in-1 system

Green 16 and 18 combine four essential imaging capabilities in one unit: panoramic, cephalometric, CBCT and model scanning.

This compact all-in-one solution reduces equipment footprint while increasing clinical versatility.

Low dose with high quality

Traditionally, lower radiation meant compromised image quality. Vatech’s Green 16/18 overcomes this by delivering sharp, clinically usable images at low dose levels, improving patient safety without sacrificing diagnostic confidence.

Multi FOV selection

With a range of field of view options including 5×5, 8×9, 12×9, 16×9 and 18×10, you can target specific regions like endo, full arch, sinus or TMJ. This reduces unnecessary radiation and tailors imaging to each case.

ART-V metal artifact reduction

Metal artifacts can obscure diagnostic details. The ART-V feature reduces these distortions, giving you clearer images for more accurate planning, especially in implant cases.

Green scan time

Shorter scan times reduce the risk of motion artifacts and improve workflow efficiency.

With panoramic scans in as little as 4 seconds and CBCT scans as fast as 2.9 seconds, patient comfort and image clarity are both enhanced.

3D model scanning

Digitise plaster models easily for digital storage and future reference. This adds convenience to your lab workflow and supports a fully digital environment.

Ez3D-i software

Streamline diagnostics and treatment planning with Ez3D-i’s intuitive tools.

It supports airway volume measurement for sleep apnea evaluation and a dedicated TMJ layout for quicker, more accurate diagnoses.

Specification

Specifications:

  • Function: CT + Pano + Ceph (optional) + Model Scan

  • Focal spot size: 0.5 mm (IEC 60336)

  • CT FOV sizes: 5×5, 8×5, 8×9, 12×9, 16×9, 16×15 (Double Scan), 18×10 cm (Green 18 only)

  • Voxel sizes:

    • 5×5: 0.08 mm / 0.12 mm

    • 8×5 / 8×9: 0.12 mm / 0.2 mm

    • 12×9: 0.2 mm / 0.3 mm

    • 16×9 / 18×10: 0.2 mm / 0.3 mm

    • 16×15: 0.3 mm / 0.4 mm

  • Scan times:

    • Pano: 4.0 sec / 14.1 sec

    • Ceph: 1.9 sec / 4.9 sec

    • CBCT: 2.9 sec / 9.0 sec

  • Gray scale: 14 Bit

  • Tube voltage/current: 60–99 kVp / 4–16 mA

  • Weight:

    • Without Ceph: 165.9 kg (no base) / 220.9 kg (with base)

    • With Ceph: 190.9 kg (no base) / 245.9 kg (with base)

  • Dimensions:

    • Without Ceph: 1085.0 mm (L) x 1343.5 mm (W) x 2315.4 mm (H) – no base

    • With Ceph: 1905.5 mm (L) x 1374.9 mm (W) x 2315.4 mm (H) – no base

    • Height with base: +30 mm